ON STAGE 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate online

Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 9 of 50 
 
Measurement of conducted emission 
4.1 Standards 
Generic standard 
 / 
Product or product family standard 
EN 55022:2006 
Limit class 
Class B 
Basic standard 
CISPR 16 
Date of testing  
 2008-08-29 
4.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer 
EMI Test Receiver 
January 25, 2008 ESCS30 
SB2603 
Rohde & Schwarz  
AMN 
January 25, 2008 ESH2-Z5 
SB3321 
Rohde & Schwarz  
Limiter 
January 30, 2008 ESH3-Z2 
SB3319/01 
Rohde & Schwarz  
4.3 Test set-up 
The test set-up was realized in a shielded chamber according to the above-mentioned standard. If 
more details are necessary, e.g. because of wiring or auxiliary equipment, annex B with a photo or a 
rough figure of the test set-up is attached. 
 
The test has been performed as following: 
1)  Preview test; Peak- and Average-Detector; measuring time 1 ms; 
frequency step 4 kHz; all lines; 
2)  Find frequencies with maximum emission: 
Acceptance-analysis: Limit minus 10dB 
Peak-reduction:10Peaks frequency range 150 kHz - 30 MHz 
3)  Final test; Quasi-Peak and Average-Detector; measuring time 1 s; 
at frequencies from step 2).
 IF Bandwidth: 9kHz
 
4)  If there are more than 10 peaks within the 10 dB margin a manual test with all settings is 
necessary to find the maximum readings. 
The EUT was placed on the top of an insulating table 0.8 meters above the ground at a shielded 
room. The EUT was placed 0.4 meters from the conducting wall of shielded room with EUT being 
connected to the power mains through a line impedance stabilization network (LISN). The LISN 
provide 50Ohm/50μH of coupling impedance for the measuring instrument. Both lines of the power 
mains connected to the EUT were checked for maximum conducted interference. The frequency 
range from 150kHz to 30MHz was searched.  The worst-case emissions are reported. 
4.4 Test result 
Power ports 
AC input 
Mode 
Diagram  
Remarks 
Result 
Diagram
  001  
Line  L   
Pass 
TM 1 
 
Diagram
  002  
Line  N 
Pass 
Diagram
  003  
Line  L   
Pass 
TM2  
Diagram
  004 
Line  N 
Pass 
Page of 50