ON STAGE 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 6

Read JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate online

Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 6 of 50 
2 Summary 
Immunity 
2.1 Standards 
Generic standard 
As below 
Product or product family standard 
EN55024:1998+A1:2001+A2:2003 
Product category: 
Performance criteria: 
see table below 
2.2 Results 
Environmental 
phenomena 
Port / Test module 
Generic standard and test 
setup 
Performance criteria 
Result 
Electrostatic 
discharge, ESD 
Enclosure 
EN 61000-4-2:1995/A1:
1998/A2:2001 
B Pass 
Radiated immunity 
Enclosure 
80 - 1000 MHz 
EN 61000-4-3:2006 
A Pass 
Electrical Fast 
Transients/Bursts 
Immunity 
Input AC power ports 
EN 61000-4-4:2004 
B Pass 
Surge Immunity 
Input AC power ports 
EN 61000-4-5:2006 
B Pass 
Conducted Immunity 
Input AC power ports  
EN 61000-4-6:1996/A1:2001 
A Pass 
Voltage dips and 
interruptions 
Immunity 
Input AC power ports 
EN 61000-4-11:2004 
B for 0% 0.5 
C for 0% 250 
C for 70% 25 
Pass 
Power frequency 
magnetic fields 
Enclosure port 
EN 61000-4-8:1993/A1:2001 
N/A*** 
***) 
No magnetic sensitive components ,so not applicable . 
2.3 Performance criteria according to product or product family standards
 
Performance criterion A 
The equipment shall continue to operate as intended without operator intervention. No degradation 
of performance or loss of function is allowed below a performance level specified by the 
manufacturer when the equipment is used as intended. The performance level may be replaced by a 
permissible loss of performance. If the minimum performance level or the permissible performance 
loss is not specified by the manufacturer, then either of these may be derived from the product 
description and documentation, and by what the user may reasonably expect from the equipment if 
used as intended. 
 
Performance criterion B 
After the test, the equipment shall continue to operate as intended without operator intervention. No 
degradation of performance or loss of function is allowed, after the application of the phenomena 
below a performance level specified by the manufacturer, when the equipment is used as intended. 
The performance level may be replaced by a permissible loss of performance. During the test, 
degradation of performance is allowed. However, no change of operating state or stored data is 
allowed to persist after the test. If the minimum performance level (or the permissible performance 
loss) is not specified by the manufacturer, then either of these may be derived from the product 
description and documentation, and by what the user may reasonably expect from the equipment if 
used as intended. 
 
Performance criterion C
 
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the 
operation of the controls by the user in accordance with the manufacturer’s instructions. Functions, 
and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.
 
Page of 50
Display

Click on the first or last page to see other ON STAGE 200ID (serv.man2) service manuals if exist.