6 Harmonic
current
6.1 Standard
Basic standard
EN 61000-3-2:2006
Date of testing
2008-09-02
6.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Power
February 20, 2008 5001ix-CTS-400
SB2588
CI
Three Phase Harmonic
flicker test system
flicker test system
February 20, 2008 PACS-3
SB2588/01 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/02 CI
Power
February 20, 2008 5001ix-CTS-400-NO SB2588/03 CI
6.3 Test set-up
See annexe B
See annexe B
6.4 Classification of EUT
Devices with an active input power
of P <75 W
of P <75 W
Balanced three-phase equipment and all other
equipment, expect that stated in one of the
following classes
equipment, expect that stated in one of the
following classes
Class A
Portable tools
Class B
Lightning equipment, including dimming devices
Class C
Equipment having an input current with a "special
wave shape" as defined in figure 1 in the
standard and an active input power, P
wave shape" as defined in figure 1 in the
standard and an active input power, P
≤ 600 W
and motor driven with phase angle control
Class D
The power cord of the EUT is connected to the output of the test systems , Turn on the power of the
EUT and use the test system to test the harmonic current level.Observation time: 150s
EUT and use the test system to test the harmonic current level.Observation time: 150s
If Harmonic current less than 0.6% of the input current measured under the test condition ,or less
than 5mA, then whichever is greater,are disregarded.
than 5mA, then whichever is greater,are disregarded.