ON STAGE 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 19

Read JBL ON STAGE 200ID (serv.man2) EMC - CB Certificate online

Ident. Nr.: 
111931 
Date:  
2008-09-09 
 
111931 EMC TRF_verified 
page 19 of 50 
 
6 Harmonic 
current 
6.1 Standard 
Basic standard 
EN 61000-3-2:2006 
Date of testing 
2008-09-02 
6.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer
Power 
February 20, 2008  5001ix-CTS-400 
SB2588 
CI 
Three Phase Harmonic 
flicker test system 
February 20, 2008  PACS-3 
SB2588/01  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/02  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/03  CI 
6.3 Test set-up 
See annexe B   
6.4  Classification of EUT 
Devices with an active input power 
of P <75 W 
 
 
Balanced three-phase equipment and all other 
equipment, expect that stated in one of the 
following classes 
Class A  
 
 
Portable tools 
Class B  
 
Lightning equipment, including dimming devices 
Class C  
 
Equipment having an input current with a "special 
wave shape" as defined in figure 1 in the 
standard and an active input power, P 
≤ 600 W 
and motor driven with phase angle control 
Class D  
 
The power cord of the EUT is connected to the output of the test systems , Turn on the power of the 
EUT and use the test system to test the harmonic current level.Observation time: 150s 
If Harmonic current less than 0.6% of the input current measured under the test condition ,or less 
than 5mA, then whichever is greater,are disregarded. 