ON CALL (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 8

Read JBL ON CALL (serv.man4) EMC - CB Certificate online

 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-009 
Page 8 of 26 
 
4.0
 
EMISSION TEST RESULT 
 
4.1        Radiated Emission 
 
 
Testing was performed in accordance with CISPR 13. 
 
4.1.1 
Test Methodology 
 
Measurements  from  30  MHz  to  1000  MHz  are  taken  with  broadband  antennas.  The  mast  to  support  the 
antennas is capable of a 1 to 4 meter height range, which meets CISPR and FCC requirements. The antenna 
mast is non-conductive and remotely controllable. 
 
Since radiated emissions, and to a lesser extent, conducted emissions, are a function of cable placement, the 
cable placement is varied to encompass all configurations that an end user would encounter to determine the 
configuration resulting in maximum emissions. At least one cable for each I/O port type is attached to the EUT. 
If peripherals or modules are available, at least one of each available type is installed and noted in the report. 
Generally, only one of each type is used unless good engineering judgment dictates that the use of more will 
affect emission levels. Excess cable lengths are arranged into a 30 x 40cm bundle. Cables requiring non-
standard lead dress are recorded in the report. 
 
4.1.2 
Site and Test Description 
 
The test facility is a specially designed and constructed open area test site. Two test sites are used (Distances: 3 
meters and 10 meters) for CISPR and FCC testing. 
 
All test sites include a metal ground plane constructed of 22-gauge sheet metal. Each site contains a 2.5 meter 
diameter turntable for floor standing equipment, and a wooden table measuring 1.5 x 1.5 x 0.8 meters for table 
top equipment to facilitate testing, also it has heat and air conditioning systems to control environmental test 
conditions. 
 
Radiated emission measurements were performed according to the procedures in ANSI C63.4 (2003). All 
measurements were performed in Open Area Test Sites. 