ON BEAT MINI - JBL Audio EMC - CB Certificate (repair manual). Page 11

Read JBL ON BEAT MINI EMC - CB Certificate online

 
Page 10 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
2.1.1 
Protection in operator access areas  
No hazardous parts in 
operator access areas. 
2.1.1.1 
Access to energized parts 
 
 
Test by inspection  .................................................. : 
Cannot touch live part or 
basic insulation 
 
Test with test finger (Figure 2A)  ............................ :  
N/A 
 
Test with test pin (Figure 2B)  ................................ :  
N/A 
 
Test with test probe (Figure 2C)  ............................ :  
N/A 
2.1.1.2 
Battery compartments  
No such battery 
compartments. 
N/A 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV 
accessible to the operator. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No such accessible 
hazardous voltage circuit 
wiring 
N/A 
2.1.1.5 
Energy hazards 
 ...........................................  : 
No accessible energy 
hazards 
N/A 
2.1.1.6 
Manual controls 
No such controls  
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
 
N/A 
 
Measured voltage (V); time-constant (s) ................ :  
 
2.1.1.8 
Energy hazards – d.c. mains supply 
Not connected to d.c mains 
supply 
N/A 
 
a) Capacitor connected to the d.c. mains supply  .. :  
N/A 
 
 N/A 
2.1.1.9 Audio 
amplifiers  ..................................................... : 
See Cl. 2.1.1.1  
2.1.2 
Protection in service access areas 
No such service access areas 
N/A 
2.1.3 
Protection in restricted access locations 
No such restricted access 
locations 
N/A 
 
2.2 SELV 
circuits 
2.2.1 
General requirements 
Class III equipment (supplied
by SELV). 
2.2.2 
Voltages under normal conditions (V)  ................... : 
< 60V  d.c. or <42.4Vpk. 
2.2.3 
Voltages under fault conditions (V)  ....................... : 
< 60V  d.c. or <42.4Vpk 
2.2.4 
Connection of SELV circuits to other circuits  ...... : 
Connect to SELV circuit only 
 