Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online
Issue Date:
2012-10-23
Page 40 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
United Kingdom - Differences to IEC 60950-1:2005 (2nd Edition); Am 1:2009
2.6.3.3
The current rating of the circuit shall be
taken as 13 A, not 16 A.
N/A
2.7.1
To protect against excessive currents and
short-circuits in the PRIMARY CIRCUIT of DIRECT
PLUG-IN EQUIPMENT, tests according to 5.3 shall
be conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
N/A
3.2.1.1
Apparatus which is fitted with a flexible
cable or cord and is designed to be connected to a
mains socket conforming to BS 1363 by means of
that flexible cable or cord and plug, shall be fitted
with a "standard plug" in accordance with Statutory
Instrument 1786: 1994 - The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those regulations.
NOTE: "Standard plug" is defined in SI 1786: 1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
N/A
3.2.5.1
A power supply cord with conductor of 1.25
mm² is allowed for equipment with a rated current
over 10A and up to and including 13A.
N/A
3.3.4
The range of conductor sizes of flexible
cords to be accepted by terminals for equipment
with a rated current of over 10 A up to and
including 13 A is 1.25 mm² to 1.5 mm² nominal
cross-sectional area.
N/A
4.3.6
The torque test is performed using a socket
outlet complying with BS 1363 part 1:1995,
N/A