Read JBL L8400P (serv.man2) EMC - CB Certificate online
MIKES BABT PRODUCT SERVICE GmbH
Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+9424-9407-0 Fax:+9424-9407-60 Rev. No 5.0
Page 2
Electrostatic discharge
Description of the test location
Test location:
Shielded Room S3
Test specification:
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Contact discharge
- Air discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- all external locations accessible by hand
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- horizontal plate (HCP)
- vertical coupling plate (VCP)
Test result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave was disturbed. After test the sine wave and level
was ok.
Click on the first or last page to see other L8400P (serv.man2) service manuals if exist.