L8400P (serv.man12) - JBL Audio Service Manual (repair manual). Page 4

Read JBL L8400P (serv.man12) Service Manual online

L8400P Powered Sub/ Plate Amp 
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120VAC/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230VAC/50-60Hz
Yes
207-264
230
Vrms
Normal operation, MOMS required
Parameter
Spec.
Unit
QA Test 
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
n/a
n/a
Bridge type amplifier, None of the speaker 
terminals must be connected to system 
GND at any time.
Load Impedance (speaker)
4
Ohms
n/a
Nominal
Rated Output Power
450
Watts
380
1 input driven
Measuring 425 Watts Cold
THD @ Rated Power
0.5
%
1
22K filter
THD @ 1 Watt
0.1
%
0.2
22K filter
Dynamic Power
460
Watts
450
Power is the average measurement 
of the first four consecutive peaks 
of the burst signal
3/20 Cycles @ 50 Hz, burst test into 4 
Ohms, input driven 6dB above its maximum 
sensitivity, volume level at Maximum.
DC Offset
80
mV-DC
100
@ Speaker Outputs
Damping factor
>20
DF
15
Measured at amplifier board 
Measured at the speaker cable.  200 Watts, 
measured at speaker output terminals 
located at the amp board.
Input Sensitivity
Input Frequency
50
Hz
30
Nominal Freq.
Left or Right inputs 
16.6
mVrms
±2dB
To 1 Watt
Single input driven, Ap Zo=600 Ohms, LP 
ON,  Volume ctrl & crossover at max
Left & Right with LFE or LP 
filter OFF Mode selected
16.6
mVrms
±2dB
To 1 Watt
Single input driven , Ap Zo=600 Ohms, LP 
OFF,  Volume ctrl & crossover at max
Speaker/Hi Level Input
165
mVrms
±2dB
To 1 Watt
Single input driven, Ap Zo=25 Ohms, 
Normal,  Volume ctrl & crossover at max
Signal to Noise
SNR-A-Weighted
100
dBA
90
Relative to rated power (400 Watts) A-Weighting filter
SNR-unweighted
95
dBr
85
Relative to rated power (400 Watts) 22K filter
SNR rel. 1W-unweighted
70
dBr
65
Relative to 1W Output
22K filter
Residual Noise Floor
0.5
mVrms
1
Volume @max, using RMS reading 
DMM/VOM (or A/P)
Residual Noise Floor
0.5
mVrms(max)
1
Volume @max, w/ A/P Swept 
Bandpass Measurement (Line 
freq.+ harmonics)
Speaker input rejection
1.0V + RMS applied to + & - inputs 
CMRR Speaker in
>37
dB 
Reference
50 Hz, Generator GND to system 
GND
Input Impedance
Line Input (L, R,LFE)
10K
ohms
n/a
Nominal
Speaker/Hi Level Input
10K
ohms
n/a
Nominal
Filters
LP  4th order variable 
50-150
Hz
± 10
Subsonic filter (HPF) 3rd Orde
Fixed
Hz
± 10
Low pass filter OFF
Fixed
Hz
± 20
L or R input driven, LP Filter OFF
HP Speaker output  4 Ohms
200
Hz
± 10
Speaker output loaded with 4 Ohms
HP Speaker output  8 Ohms
100
Hz
± 10
Speaker output loaded with 8 Ohms
Limiter 
THD at Max. Output Power
YES
n/a
functional 
Features
--
Auto - On -Off 
YES
--
functional 
No switch to select the ATO mode is 
provided, Refer to ATO section
L
8400P 
 
series 
           
 
 
3
Page of 24
Display