Read JBL FLIP II (serv.man8) EMC - CB Certificate online
Report No.: EM201300388-5 Application No.: ZJ00030592 Page 67 of 71
FCC ID:
APIFLIP2
4.11 BAND EDGES REQUIREMENT
4.11.1 LIMITS
4.11.1 LIMITS
Section 15.247 (d) In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth
within the band that contains the highest level of the desired power, based on either an RF
conducted or a radiated measurement, provided the transmitter demonstrates compliance with the
peak conducted power limits. If the transmitter complies with the conducted power limits based on
the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section,
the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below
the general limits specified in Section 15.209(a) is not required.
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth
within the band that contains the highest level of the desired power, based on either an RF
conducted or a radiated measurement, provided the transmitter demonstrates compliance with the
peak conducted power limits. If the transmitter complies with the conducted power limits based on
the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section,
the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below
the general limits specified in Section 15.209(a) is not required.
4.11.2 TEST PROCEDURES
1. Check the calibration of the measuring instrument using either an internal calibrator or a known
signal from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and
connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any
one measured frequency within its operating range, and make sure the instrument is operated in
its linear range.
one measured frequency within its operating range, and make sure the instrument is operated in
its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency
span including 100 kHz bandwidth from band edge.
Note: For Restricted Band
RBW=100 kHz
VBW=300 kHz
RBW=100 kHz
VBW=300 kHz
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot
the graph with marking the highest point and edge frequency.
Repeat above procedures until all measured frequencies were complete.
4.11.3 TEST SETUP
4.11.4 TEST RESULTS
The unit does meet the FCC requirements.
Test result plot as follows:
EUT
Spectrum analyzer
Click on the first or last page to see other FLIP II (serv.man8) service manuals if exist.