ES150P - JBL Audio Service Manual (repair manual). Page 6

Read JBL ES150P Service Manual online

 
ES150P Test Set Up and Procedure 
 
 
Equipment needed: 
 
• Function/signal 
generator/sweep 
generator 
• Integrated 
Amplifier 
• Multimeter 
• Speaker 
cables 
 
General Unit Function (UUT = Unit Under Test) 
 
1)  From the signal generator, connect line level (RCA) cables to the Subwoofer Line Level Input jacks L/R on 
the UUT. Use a Y-cable from a mono source if necessary to connect to both inputs.  
2)  Turn the CROSSOVER control to maximum (150). 
3)  Turn the LEVEL control on the UUT to completely counterclockwise (MIN). 
4)  LFE/NORMAL switch should be in NORMAL position. 
5)  PHASE switch position does not matter. 
6)  Turn on generator; adjust to 75mV, 50 Hz
7)  Plug in UUT; turn the power switch ON. LED should switch from Red to Green.  
8)  Turn LEVEL control full clockwise (MAX); immediate and vigorous bass response should be heard and felt 
from port tube opening on the bottom. 
9)  Turn off generator, turn LEVEL control full counterclockwise (MIN), and disconnect RCA cable. 
 
Sweep Function 
 
1)  Follow steps 1-8 above, using a sweep generator as a signal source. 
2)  Sweep generator from 20Hz to 300Hz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or 
any other noises. If any unusual noises are heard, remove woofer and test. 
 
Driver Function 
 
1)  Remove woofer from cabinet; detach + and - wire clips. 
2)  Check DC resistance of woofer; it should be 3.4 ohms ±10% 
3)  Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier 
fed by a signal generator. Turn on generator and adjust so that speaker level output is 5.0V. 
4)  Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises. 
 
 ES150P 
 
 
 
 
 
 
 
 
 
 
 
   
      
 
 
 
Service Manual
Page 6 of 30
Page of 30
Display

Click on the first or last page to see other ES150P service manuals if exist.