ES 250P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL ES 250P (serv.man4) EMC - CB Certificate online

Page 7 of 47
Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
C03, C04
P
Basic insulation bridged by components complying
with 14.3.4.3
N/A
8.7
This sub-clause is void
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) .......................................:
Primary wires are double
insulated
P
Reinforced insulation > 0.4 mm (mm) ....................:
N/A
Thin sheet insulation used inside the enclosure.
In mains transformer
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
150-r1107012-e:
Two layers plastic sheet
P
Reinforced insulation, three layers any two which
meet 10.3 dielectric
TT093505270-E:
Thin sheet insulation, 4 turns
mylarfoil with a thickness of
0.08mm.
P
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
Applies to Class I appliances
N/A
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
N/A
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
Live wires from transformer are
double insulated.
No secondary wire can come
into contact with live bare parts.
P
Page of 60
Display