Report No. 707218
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
National differences Denmark
IEC 60065:2001 + A1
(See also Group Differences)
CB Bulletin 112A / DK 06 II
2.6.1
The following is added:
Certain types of CLASS I apparatus, see 15.1.1, may
be provided with a plug not establishing earthing
continuity when inserted in Danish socket-outlets
Justification:
Heavy Current Regulations, Section 107
N/A
15.1.1
To the first paragraph the following is added:
In Denmark, supply cords of single phase appliances
having a rated current not exceeding 13 A shall be
provided with a plug according to the Heavy Current
Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be provided
with a plug in accordance with the Heavy Current
Regulations Section 107-2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to CLASS II
apparatus with a rated current of 2.5 A shall have the
following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-outlets.
Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be in
compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification:
Heavy Current Regulations, Section 107
Only 1
st
paragraph
(Class II appliances and no
socket-outlets)