Read JBL ES 150PW EMC - CB Certificate online
Page 13 of 48
Report No. 806700
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14 COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors
separately approved ...............................:
N/A
14.2
Capacitors and RC units
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ...: Y1: C03, C04
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ...: X2: C01, C02
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ......................:
connected to the mains: tests for X2 ......................:
N/A
14.2.5 a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better .......................................................................:
compliance with IEC 60384-1, 4.38 category B or
better .......................................................................:
C01, C02
P
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
Only metal-cased capacitors
N/A
Shielded by a barrier per Table 21..........................: No
N/A
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
manufacturer's name and type ...............................:
Zhong Shan Yi Qi
150-R0905504-E
150-R0905504-E
P
Transformers and inductors separately approved .: No
N/A
14.3.2
General
14.3.3, 14.3.4.1 and 14.3.5.1
P
14.3.3
Constructional requirements (complete appended tables or include manufacturers
constructional insulation descriptions)
constructional insulation descriptions)
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2 Transformers
meet
the
constructional requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Primary – secondary: 9.8mm
P
Coil formers and partition walls = 0.4 mm
Thin sheet insulation
P
Click on the first or last page to see other ES 150PW service manuals if exist.