ES 150PW (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 40

Read JBL ES 150PW (serv.man4) EMC - CB Certificate online

ELECTRONICS TESTING CENTER(ETC), TAIWAN 
File No. : 08-07-RBF-038-01 
EMC TESTING DEPARTMENT II
       Page: 39 / 42 
 
 
4.2.5  RF Common Mode Immunity Test : 
4.2.5.1  RF Common Mode Immunity Test Data: 
Operating Conditions of The EUT : Operation Mode 
 
 
Test Date :  Jul. 08, 2008
Test Specification 
EN 61000-4-6:1996/A1:2001 
Equipment 
Manufacturer 
Model No. 
Calibration Date 
Next Cal. Date 
CS TESTER 
FRANKONIA 
CIT-10 
2007/09/05 
2008/09/04 
M2+3 CDN-KIT 
FRANKONIA 
M2+3 
2007/09/08 
2008/09/07 
SCHAFFUER CS-CLAMP  KEMZ801  2007/09/08  2008/09/07 
Climatic Condition 
Ambient Temperature:  25 °C Relative 
Humidity: 
57 %RH 
 
Atmospheric Pressure :    990 mbar 
Power Supply System 
AC Power :    230   Vac  50  Hz 
Test Set-up 
Floor-standing Equipment 
 
Frequency Range 
0.15 MHz ~ 80 MHz
Field Strength 
3 V/m 
Modulation (AM 1kHz 80%) 
Sweep Rate  :
≤ 1.5×10
-3
 decades/s 
Step Size :
≤ 1 % of preceding frequency value  Dwell Time  :2.9 s 
Frequency Range (MHz) 
Tested Line 
Test Result 
0.15~80 
Power Line (M2) 
Note :
   
“ A ” means the EUT function was correct during the test.
 
 
 
 
 
 
 
 
 
 
Page of 52
Display