JBL ES150P  225W Powered Sub Amp 
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120vac/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-253
230
Vrms
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
n/a
n/a
Min. Load Impedance (speaker)
4
Ohms
n/a
Nominal
AVG System impedance
5.18
Ohms
Reference 
AP Computed based on system 
impedance curve
Over the BW of 20 to 500Hz
Rated Output Power 
225
Watts
210
AVG RMS  Dynamic Power
245
Watts
240
Average RMS power,  3/20 Cycles 50 Hz, 
Driven 6dB above its input sensitivity , 
average of the first 4 consecutive peaks
THD @ Rated Power
0.5
%
1
22k filter
THD @ 1 Watt
0.2
%
0.3
22k filter
DC Offset
10
mV-DC
30
@ Speaker Outputs
Damping factor
>50
DF
20
Measured at amplifier board 
Measured at the speaker cable.  189 Watts 
@ THD < 0.1 % @ 50 Hz
Input Sensitivity
Input Frequency
50
Hz
50
Nominal Freq.
L or R Inputs
11
mVrms
±1dB
To 1 Watt
Single input driven
LFE mode using L or R inputs
11
mVrms
±1dB
To 1 Watt
Single input driven, LFE switch ON
System Gain
45
dB
Reference
Single input driven Normal or LFE mode
Signal to Noise
SNR-A-Weighted
80
dBA
75
relative to 1W
A-Weighting filter
SNR-unweighted
65
dBr
60
relative to 1W
22K filter
Residual Noise Floor
<2.0 mVrms(max)
2.5
Volume @max, w/ A/P Swept 
Bandpass Measurement (Line 
freq.+ harmonics) (BW=20 KHz)
Line level inputs must be terminated using    
1KOHM
Input Impedance
Line Input (L, R,LFE)
10K
ohms
n/a
Nominal
Filters
LP filter Variable
50-150
Hz
± 10
4th Order variable-24 db/Octave
Subsonic filter (HPF) 2nd Order
Fixed
Friend circuit
Fixed
LFE Low pass 
200>LP<500
Hz
LFE input driven only
Limiter 
THD at Max. Output Power
13
%
functional 
Drive unit 6dB above the required 
level to obtain full power 
Approximately 208mV
Maximum THD as a result of limiting.
Features
--
Volume pot Taper (lin/log)
LOG
--
functional 
A Taper
Phase switch 
0-180
deg
functional 
LP Filter defeat switch
YES
functional 
Disables LP filter, intended for LFE 
LED indicator
YES
functional 
Bicolor LED located in top of the cabinet,  
RED-Standby, GRN-Active
Input Configuration
Line In  (L,R) & LFE
YES
--
functional 
Dual  RCA jack, for LFE use either L or R inputs
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional 
ATO Input test frequency
50
Hz
functional 
ATO Level LFE Input
2
mV
functional 
Maximum acceptable level.
ATO Turn-on time
5
ms
functional 
Amp connected and AC on, then 
input signal applied
Auto Mute/ Turn-OFF Time
5-15
minutes
5-15
T before muting, after signal is 
removed
Auto turn of time (T)   must be  5 > T < 15 
Minutes
Power on Delay time
3
sec.
4
After AC Power is applied
 
 ES150P 
 
 
 
 
 
 
 
 
 
 
 
   
      
 
 
 
JBL
ES 150P/230V and EUP Service Manual
Page 3 of 41
Page of 41
Display