ES 150P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 5

Read JBL ES 150P (serv.man2) EMC - CB Certificate online

 
mikes-testingpartners gmbh
 File 
No. 
F31764-00-00HM
, page 
4 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
2   S U M M A R Y  
 
2.1 General 
remarks 
 
None 
 
2.2 
Summary for all EMC tests 
 
Type of test
 
Test result 
EMC emission: 
A4 
Conducted emissions (AC mains power / DC power) 
Fulfilled 
A5 
Radiated emissions from ancillary equipment 
Not Applicable 
A6 
Conducted emissions (Antenna port) 
Not Applicable 
A7 Disturbance 
power 
Fulfilled 
A9 
Radiated disturbance (ERP) 
Not Applicable 
FL&H 
Harmonic current emissions 
Fulfilled 
FL&H 
Voltage fluctuations and flicker 
Fulfilled 
 
Test result 
Performance 
criteria 
Immunity: 
I2 
Electrostatic discharge (ESD) 
Fulfilled 
I3 
Radio frequency electromagnetic field 
Fulfilled 
I4 
Fast transients, common mode (BURST) 
Fulfilled 
S1 
Immunity requirements 
Not Applicable 
 
S2 Immunity 
requirements 
Fulfilled 
S2c 
Immunity requirements 
Not Applicable 
 
S3 Immunity 
requirements 
Fulfilled 
S4 
Immunity requirements 
Not Applicable 
 
 
2.3 Final 
assessment 
 
The equipment under test 
fulfills the EMC requirements cited in clause 1 test standards. 
 
 
Date of receipt of test sample 
acc. to storage records 
 
 
 
Testing commenced on 
23.. May 2007 
 
 
 
Testing concluded on 
24. May 2007 
 
 
Checked by: 
Tested by: 
 
 
 
  
Michael 
Hackl 
EMC Senior Expert 
Michael Hackl 
Ich bin der Verfasser 
dieses Dokuments 
2007.05.24 21:23:26 
+02'00'
Page of 32
Display