5.7.3 Test 
specification 
 
Contact discharge voltage: 
2 kV 
4 kV 
 
Air discharge voltage: 
2 kV 
4 kV 
8 kV 
 
Discharge impedance: 
330 
Ω / 150 pF 
 
Discharge factor: 
≥ 1 sec. 
 
Number of discharges: 
≥ 10 
 
Type of discharge: 
Direct discharge: 
- Contact discharge 
 
- Air discharge 
 
Indirect discharge: 
- Contact discharge 
 
Polarity: 
- positive 
- negative 
 
Discharge location: 
- all external locations accessible by hand 
- see photo documentation of the test set-up 
- vertical coupling plate (VCP) 
- horizontal plate (HCP) 
 
5.7.4 Test 
result 
 
The requirements are 
FULFILLED. 
Performance Criterion:
 B 
 
Remarks: 
During electrostatic discharge clicks are audible.  
 
 
 
 
 
 
 
 
 