EMC - CB Certificate (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate online

Issue Date: 
2014-08-11 
Page 10 of 43 
Report Reference #
BTL-CB-1-S1407C070
 
 
 
 
 IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1F 
 
 
 
 
1.7.8 
Controls and indicators 
See below. 
1.7.8.1 
Identification, location and marking  .......................: The function of controls 
affecting safety is obvious 
without knowledge of 
language etc. 
1.7.8.2 Colours 
 
 .................................................................: Only functional indicators use 
colour. 
1.7.8.3 Symbols 
according to IEC 60417 ...........................:  
N/A 
1.7.8.4 
Markings using figures  ..........................................: No control. N/A 
1.7.9 
Isolation of multiple power sources  .......................:  
N/A 
1.7.10 
Thermostats and other regulating devices  ............: No thermostats or other 
regulating devices. 
N/A 
1.7.11 Durability 
The marking withstands 
required tests. 
1.7.12 
Removable parts 
No removable parts. 
N/A 
1.7.13 Replaceable 
batteries  ............................................: The required warning is in 
both the operation and service 
manuals. 
 Language(s) 
 
..........................................................: Only English language 
reviewed. The other 
languages will be provided 
during the national approval. 
 
1.7.14 
Equipment for restricted access locations ..............: Equipment not intended for 
installation in a RESTRICTED 
ACCESS LOCATION. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
The equipment includes SELV 
circuits, no electric shock or 
energy hazards, for details 
see below. 
2.1.1.1 
Access to energized parts 
See subclause 2.1.1. 
N/A 
 
Test by inspection  ..................................................:  
N/A 
 
Test with test finger (Figure 2A)  ............................:  
N/A 
 
Test with test pin (Figure 2B)  ................................:  
N/A 
 
Test with test probe (Figure 2C)  ............................: Not  applicable. 
N/A 
2.1.1.2 
Battery compartments  
 
N/A 
2.1.1.3 
Access to ELV wiring 
 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
 
 
Page of 127