Read JBL EMC - CB Certificate (serv.man6) EMC - CB Certificate online
Issue Date:
2014-08-11
Page 10 of 43
Report Reference #
BTL-CB-1-S1407C070
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
1.7.8
Controls and indicators
See below.
P
1.7.8.1
Identification, location and marking .......................: The function of controls
affecting safety is obvious
without knowledge of
language etc.
without knowledge of
language etc.
P
1.7.8.2 Colours
.................................................................: Only functional indicators use
colour.
P
1.7.8.3 Symbols
according to IEC 60417 ...........................:
N/A
1.7.8.4
Markings using figures ..........................................: No control. N/A
1.7.9
Isolation of multiple power sources .......................:
N/A
1.7.10
Thermostats and other regulating devices ............: No thermostats or other
regulating devices.
N/A
1.7.11 Durability
The marking withstands
required tests.
required tests.
P
1.7.12
Removable parts
No removable parts.
N/A
1.7.13 Replaceable
batteries ............................................: The required warning is in
both the operation and service
manuals.
manuals.
P
Language(s)
..........................................................: Only English language
reviewed. The other
languages will be provided
during the national approval.
languages will be provided
during the national approval.
1.7.14
Equipment for restricted access locations ..............: Equipment not intended for
installation in a RESTRICTED
ACCESS LOCATION.
ACCESS LOCATION.
N/A
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
The equipment includes SELV
circuits, no electric shock or
energy hazards, for details
see below.
circuits, no electric shock or
energy hazards, for details
see below.
P
2.1.1.1
Access to energized parts
See subclause 2.1.1.
N/A
Test by inspection ..................................................:
N/A
Test with test finger (Figure 2A) ............................:
N/A
Test with test pin (Figure 2B) ................................:
N/A
Test with test probe (Figure 2C) ............................: Not applicable.
N/A
2.1.1.2
Battery compartments
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
Click on the first or last page to see other EMC - CB Certificate (serv.man6) service manuals if exist.