E 250P (serv.man15) - JBL Audio Service Manual (repair manual). Page 11

Read JBL E 250P (serv.man15) Service Manual online

E250P
 Testing Procedure 
POWER MODULE TESTING FLOW CHART
CAUTION : SPEAKER OUTPUT IS FLOATING AND IS  NOT  PROTECTED AGAINST A SHORT
                           TO  GROUND.  ALL TEST INSTRUMENTS CONNECTED TO THE OUTPUT MUST
                           BE  FLOATING.  ATTACH  THE  SCOPE  PROBE TIP TO S - and  REFERENCE
                           LEAD TO S+.
                                                   (A 10mV signal may need from the input to trigger the Switch turn on)
                                                                                                                                 no
                     no
                                                                                                                           yes
              yes
                                                                                                                                 no
                     no
                                                                                                                           yes
              yes
                                                                                                                                 no
                     no
                                                                                                                           yes
              yes
                                                                                                                                 no
                     no
                                                                                                                          yes
               yes
START
Check +/-15V-MOD
+/-15V voltage  at
U 6(8),U6(4)
Discharge C37,
Check fuse
transformer, L4,
rectifier, C6 and C8
Use scope to check
switching
frequency U6(7)
100KHz
 +/-10% , ~24Vp-p
Check Q4(E)
TO V-
 = 0V D.C.
Power up with no
signal input
LED RED
OK
OK
OK
OK
OK
OK
OK
OK
Check
MUTE(+8V) and
Q24,Q25,Q26
Use scope to
check O/P U7(6)
and GND
143Vp-p square
wave shown
Check
L2,L3,C71,C72,
C73,C74
I/P:10mv/50HZ
Check +15V/SW
Q4(E) TO V-
15V
Replace
Q18,Q22
CLASS  D AMP OK
END
Check
U7,Q16,Q17,
Q20,Q21,R87,
D26,D35,C64
Check
FB1,FB2,C45,
C50,C60,C63,
R81,R82
Check
U7(1) = -58.3V
Check
MUTE
(-12.9V),
And
Q24,Q25,Q26
Resistance check
(no load)
between V+ V-,
V+ O/P,V- O/P
and O/P to GND
is > 10K
Page of 15