E 150P (serv.man14) - JBL Audio Service Manual (repair manual). Page 10

Read JBL E 150P (serv.man14) Service Manual online

E150P
Testing Procedure 
 - Voltage measurements
OP AMP
U2(1)
U2(14)
U2(8)
U3(7)
U3(1)
U3(14)
U3(8)
U5(7)
U5(1)
SPEAKER
O/P
133.6mV
200.2mV
245.9mV
314.8mV
314.9mV
350mV
1.67V
1.452V
2.098V
15.3V
2. High Level Input Sensitivity
     -Set up
Turn level, X’OVER FREQ POT Fully CW and LFE switch off
                             
Set Generator at 1.15V@50Hz
Signal to High level input
     -Voltage measurements 15.3V at speaker output
3. Low-Pass
    -Set up
Set Generator at 100 mV@100Hz
Signal to 
Line
 level input
Measure voltage at S+ speaker output
     -Voltage measurement
X’OVER FREQ. Setting
Output
CW
10.72V
CCW
2.165V
4. LFE 
     -Set up
Set Generator at 100mV@200Hz
Signal to 
Line
 level input
Measure voltage at S+ speaker output
LFE  switch  Setting
Output
Normal
2.9V
LFE
7.62V
See flow chart next page for diagnostics.