DUET II (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL DUET II (serv.man7) EMC - CB Certificate online

 
 
- Page 10 of 51 - 
 
 
www.nemko.com
 
Report No.  114383 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
1.7.8.1 Identification, 
location 
and marking  ....................:
No control. 
N/A 
1.7.8.2 Colours 
...............................................................:
No indicators with colours 
where safety is involved. 
N/A 
1.7.8.3 Symbols 
 .............................................................:
There is no switch in the 
equipment, function control is 
marked with “+” and “-” for 
volume control. 
N/A 
1.7.8.4 Markings 
using figures  ......................................:
 
N/A 
1.7.9 
Isolation of multiple power sources ....................:
Class III equipment. 
N/A 
1.7.10 
IT power distribution systems  
Class III equipment. 
N/A 
1.7.11 
Thermostats and other regulating devices  
No thermostats or other 
regulating devices.  
N/A 
1.7.12 Language 
............................................................:
Instructions and markings shall 
be in a language acceptable for 
the country where the 
equipment is to be used. 
— 
1.7.13 
Durability 
The marking withstands 
required tests. 
1.7.14 
Removable parts 
No removable parts. 
N/A 
1.7.15 
Replaceable batteries 
No battery in the equipment. 
N/A 
 Language.............................................................:
 
— 
1.7.16 
Operator access with a tool.................................:
All areas containing hazard(s) 
are inaccessible to the 
operator. 
N/A 
1.7.17 
Equipment for restricted access locations...........:
Equipment not intended for 
installation in RAL. 
N/A 
 
PROTECTION FROM HAZARDS 
 
2.1 
Protection from electric shock and energy hazards 
 
2.1.1 
Protection in operator access areas  
Refer below: 
— 
2.1.1.1 
Access to energized parts  
Class III equipment. 
N/A 
 Test 
by 
inspection ...............................................:
 
N/A 
 Test 
with 
test finger  ............................................:
 
N/A 
 Test 
with 
test pin .................................................:
 
N/A 
 Test 
with 
test probe ............................................:
 
N/A 
2.1.1.2 Battery 
compartments 
........................................:
No TNV circuits in the 
equipment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV 
accessible to the operator. 
N/A 
Page of 87