DUET II (serv.man5) - JBL Audio EMC - CB Certificate (repair manual). Page 21

Read JBL DUET II (serv.man5) EMC - CB Certificate online

Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 21 of 38 
7.5 Table 
7.5.1 Table 006 
Flicker Test Summary per EN/IEC61000-3-3  (Run time) 
 
EUT: Duet II 
Tested by: Test Operator 
Test Margin: 100 
Test date: 10/29/2008 
Start time: 3:56:47 PM 
End time: 4:07:08 PM 
Test duration (min): 10 
Data file name: F-000850.cts_data 
Comment: Connect to PC(Play MP3) 
Customer: Customer 
 
Test Result: Pass 
Status: Test Completed 
 
 
Pst
i
 and limit line  
 
Limits 
0.25
0.50
0.75
1.00
  
Pst
16:07:07
 
Plt and limit line  
0.0
0.1
0.2
0.3
0.4
0.5
0.6
  
Plt
16:07:07
 
Parameter values recorded during the test: 
Vrms at the end of test (Volt): 
230.05 
Highest dt (%): 
0.00 
Test limit (%): 
3.30 
Pass 
Time(mS) > dt:   
0.0 
Test limit (mS): 
500.0 
Pass 
Highest dc (%): 
0.00 
Test limit (%): 
3.30 
Pass 
Highest dmax (%): 
0.00 
Test limit (%): 
4.00 
Pass 
Highest Pst (10 min. period):         0.064 
Test limit:                1.000 
Pass  
 
 
Page of 38