Read JBL DUET II (serv.man3) EMC - CB Certificate online
- Page 60 of 65 -
Report
No.
114383
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.5
TABLE: Thermal requirements
P
Supply voltage (V) .....................
264V/60Hz(adapter)
⎯
Maximum measured temperature T of
part/at::
part/at::
T (
°C)
Allowed
T
max
(
°C)
Supplied 1KHz sine wave for speakers in computer speaker system and obtain 1/8 Maximum non-clipped
output power
output power
Adapter enclosure
44.7
81
C20 body (rated 105
°C)
83.4 91
C10 body (rated 105
°C)
65.2 91
Heating sink near U6
104.2
--
PCB near U6
98.4
116
Enclosure inside near Heating sink
53.3
--
Enclosure outside near back
37.5
81
Ambient 26.0
--
Having a specified maximum ambient temperature of 40°C, the maximum temperatures are calculated
based upon a (minimum) test temperature of 26°C. Temp. limits are adjusted according to Cl. 1.4.12.3.
Temperature limits include less 10K for thermocouple measurement method.
based upon a (minimum) test temperature of 26°C. Temp. limits are adjusted according to Cl. 1.4.12.3.
Temperature limits include less 10K for thermocouple measurement method.
Temperature T of winding:
t
1
(°C)
R
1
(
Ω)
t
2
(°C)
R
2
(
Ω)
T (
°C)
Allowed
T
max
(
°C)
Insulatio
n class
supplementary information: