No. 
114383 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
4.5 
TABLE: Thermal requirements 
 
Supply voltage (V)  .....................
264V/60Hz(adapter) 
⎯ 
Maximum measured temperature T of 
part/at:: 
T (
°C) 
Allowed 
T
max
 (
°C)
Supplied 1KHz sine wave for speakers in computer speaker system and obtain 1/8 Maximum non-clipped 
output power 
Adapter enclosure 
44.7 
81 
C20 body (rated 105
°C) 
83.4 91 
C10 body (rated 105
°C) 
65.2 91 
Heating sink near U6 
104.2 
-- 
PCB near U6 
98.4 
116 
Enclosure inside near Heating sink 
53.3 
-- 
Enclosure outside near back 
37.5 
81 
Ambient 26.0 
-- 
Having a specified maximum ambient temperature of 40°C, the maximum temperatures are calculated 
based upon a (minimum) test temperature of 26°C. Temp. limits are adjusted according to Cl. 1.4.12.3. 
Temperature limits include less 10K for thermocouple measurement method. 
Temperature T of winding: 
t
1
 (°C)
R
1
 (
Ω)
t
2
 (°C)
R
2
 (
Ω)
T (
°C) 
Allowed 
T
max
 (
°C)