Read JBL DUET II (serv.man3) EMC - CB Certificate online
- Page 52 of 65 -
Report
No.
114383
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.5.1
TABLE: List of critical components
P
Object/part No. Manufacturer/
trademark
Type/model
Technical data
Standard
(Edition / year)
Mark(s) of
conformity
1
)
Adaptors JBL
S024Ez1800120
(z can be V, B,
U, C and M)
(z can be V, B,
U, C and M)
Input:
100-240Vac,
50/60Hz, 0.6A
Max,Class II
Output:
18VDC, 1.2A
100-240Vac,
50/60Hz, 0.6A
Max,Class II
Output:
18VDC, 1.2A
IEC 60950-1
TUV
(CB
certificate
No. JPTUV-
014962)
(CB
certificate
No. JPTUV-
014962)
Enclosure
Various
Various
Min. HB, min.
Thickness 3.09mm,
100ºC
Thickness 3.09mm,
100ºC
UL 94
UL
PCB
Various
Various
Min. V-1 or better,
130 ºC
130 ºC
UL 94
UL
Various
Various
300V, min: 80ºC
UL 758
UL
Various
Various
Min. V-2
IEC 60950-1
Tested in
equipment
equipment
Power amplifier
IC(U6)
IC(U6)
ST
TDA2007
12W
IEC 60950-1
Tested in
equipment
equipment
Speaker x2
Various
Various
4ohm, 6.76W
IEC 60950-1
Tested in
equipment
equipment
supplementary information: