Read JBL CSS EMC - CB Certificate online
page 9 of 32
Ref. No.: 515949
IEC 60065
Cl.
Requirement - Test
Result - Remark
Verdict
12 MECHANICAL
STRENGTH
12.1.1 Bump
test
P
12.1.2
Vibration test
No connection of part, which
might impair safety, can
become loose.
might impair safety, can
become loose.
P
12.1.3 Impact
test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
13
CLEARANCES AND CREEPAGE DISTANCES
13.1
Clearances and creepage distances in accordance
with 13.2 (fig. 9); minimum distance ..................... :
with 13.2 (fig. 9); minimum distance ..................... :
Prim. – sec.=>10mm
Prim. – Accessible parts=6mm
P
13.1.1
Reduction applied if the 3 conditions are met ....... : No
N/A
Reduction applied for Grade 2 winding wire ......... : No
N/A
13.1.2
Use of cemented joints .......................................... : No
N/A
Tests to confirm cemented joints
N/A
13.2
Clearances and creepage distances of parts of
different polarity connected to the mains, as in
fig. 9; minimum distance ....................................... :
different polarity connected to the mains, as in
fig. 9; minimum distance ....................................... :
3.5mm
P
Clearances
and
creepage
distances
between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
may be conductively connected to the mains, as in
fig. 10
N/A
13.3
Enclosed, enveloped or hermetically sealed parts:
clearances and creepage distances to Table 4
clearances and creepage distances to Table 4
N/A
13.4
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
13.5
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
Click on the first or last page to see other CSS service manuals if exist.