CS680 - JBL Audio EMC - CB Certificate (repair manual). Page 33

Read JBL CS680 EMC - CB Certificate online

 
 
page 29 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
ZB 
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class 
Ι apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
 N/A 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
 P 
 
DK: Class 
Ι equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
 N/A 
 
DK: socket-outlets for providing power to Class 
ΙΙ 
equipment with a  rated current of 2.5 A shall have 
dimensions according to the drawing on page 131 
of EN 60065:98 other dimensions shall be to 
IEC 60083 Standard Sheet C 1a for portable 
socket-outlets 
 N/A 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
 N/A 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
The power supply cord set was 
not evaluated together with the 
apparatus. A suitable certified 
power supply cord set has to 
be added in the country where 
the apparatus is sold. 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
See above 
 
NO: mains socket-outlets on Class 
ΙΙ equipment meet CEE Publication 7 with the 
following amendments: 
N/A 
 
- dimensions 2.5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60065:98 
 N/A 
 
- mechanical strength 2.5 A, 250 V socket-outlets 
tested as specified in EN 60065, 12.1.3 
 N/A 
 
- protecting rim also tested 
 
N/A 
B.5.4.1 
NO: marking required for equipment connected to 
a communications network other than the public 
telecommunications network, where separation 
between the mains and the network relies upon a 
safety earth connection 
 N/A 
 
Page of 48
Display