Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min.
after surge test for basic and 4 MΩ min. for
reinforced insulation .......................................... :
after surge test for basic and 4 MΩ min. for
reinforced insulation .......................................... :
No antenna terminal
N/A
10.2
Humidity treatment 48 h or 120 h ..................... : Both 48 h and 120 h
P
10.3
Insulation resistance and dielectric strength
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
No flaming more than 10s
P
Soldered terminations not used as protective
mechanism
mechanism
N/A
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards
(PCB) exceeding the limits of table 3 by max.
100 K for max. 5 min
(PCB) exceeding the limits of table 3 by max.
100 K for max. 5 min
N/A
a) Temperature rise of printed circuit boards
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm²
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm²
N/A
b) Temperature rise of printed circuit boards
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm² for a maximum of 5 min
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
At Uin=198V, voltage across
interruption <50Vp
At Uin=253V, no interruption, mains
fuse broke
interruption <50Vp
At Uin=253V, no interruption, mains
fuse broke
(see table 11)
At Uin=198V,
voltage across interruption <50Vp
At Uin=253V, no interruption, mains
fuse broke
At Uin=253V, no interruption, mains
fuse broke
(see table 11)
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
P