CS - JBL Audio EMC - CB Certificate (repair manual). Page 39

Read JBL CS EMC - CB Certificate online

 
Page 36 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
 
 
National differences  Denmark 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CB Bulletin 112A / DK  06 II
 
 
2.6.1 
The following is added: 
Certain types of CLASS I apparatus, see 15.1.1, may 
be provided with a plug not establishing earthing 
continuity when inserted in Danish socket-outlets 
Justification: 
Heavy Current Regulations, Section 107 
 N/A 
15.1.1 
To the first paragraph the following is added: 
In Denmark, supply cords of single phase appliances 
having a rated current not exceeding 13 A shall be 
provided with a plug according to the Heavy Current 
Regulations Section 107-2-D1. 
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used in 
locations where protection against indirect contact is 
required according to the wiring rules shall be provided 
with a plug in accordance with the Heavy Current 
Regulations Section 107-2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added: 
Socket outlets intended for provided power to CLASS II 
apparatus with a rated current of 2.5 A shall have the 
following dimensions: 
 
 
Dimensions in mm 
 
Other dimensions shall be in compliance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DKA 1-3 for portable socket-outlets. 
Shutters are not required. 
To the third paragraph the following is added: 
Mains socket-outlets with earthing contact shall be in 
compliance with the Heavy Current Regulations, 
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-5a 
or DK 1-7a. 
Justification
Heavy Current Regulations, Section 107 
 P 
 
 
Page of 58
Display

Click on the first or last page to see other CS service manuals if exist.