Read JBL CS (serv.man2) EMC - CB Certificate online
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
23 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.7.3 Test
specification
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Contact discharge
- Air discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- all external locations accessible by hand
- see photo documentation of the test set-up
- vertical coupling plate (VCP)
- horizontal plate (HCP)
- see photo documentation of the test set-up
- vertical coupling plate (VCP)
- horizontal plate (HCP)
5.7.4 Test
result
The requirements are
FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave disappears and then reappears by itself.
Click on the first or last page to see other CS (serv.man2) service manuals if exist.