CINEMA 610 - JBL Audio EMC - CB Certificate (repair manual). Page 22

Read JBL CINEMA 610 EMC - CB Certificate online

 
 
 
 
Page 21 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
20 
Resistance to fire 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 
N/A 
 
b) Exemption for small components as defined in 
20.1  
 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4  
 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
No working voltages > 4 kV 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure  
PCB with flammability category 
V-0 used. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
PCB with flammability category 
V-0 used. 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
(see appended table)  
Foam on secondary wires is  
V-1 or better.  
Wooden enclosure with 
thickness 9.0mm considered 
as V-1 fire enclosure. 
Distance between PIS and HB 
enclosure more than 60mm. 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 
N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 
N/A 
20.2.2 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
Page of 108
Display