Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online
Page 42 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
National
differences
SINGAPORE
IEC 60065:2001
NOTE: (These differences are taken from IEC 60065:1993 and adopted to
IEC 60065:2001)
CB / SG 2006 I
Throughout the standard,
whenever the words
"white pine board" appear, insert the words "or
plywood board" to it.
plywood board" to it.
P
SS143 Amendment No. 1 and No. 2
4.1.3
(4.1.3)*
Delete "45 % to 75 % and insert "65 ± 5 %".
75% maximum in IEC
60065:2001
60065:2001
P
7.1
(7.1)
Resistance to heat without external forces.
Adopt the temperature specified for the tropical
conditions.
conditions.
P
8.6
(9.3.4)
Delete the note "A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:2001
P
10.2
(10.2)
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
conditions.
120h at 93% rel. humidity
P
16
(16)
External flexible cords
Delete "IEC Publication 60227: Polyvinyl Chloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
P
16.2
(16.2)
Delete the notes in small print and insert "A
nominal cross-sectional area of 0.75 mm² will
satisfy this requirement".
nominal cross-sectional area of 0.75 mm² will
satisfy this requirement".
This is not in IEC 60065:2001
P
Click on the first or last page to see other BALBOA SUB10 (serv.man2) service manuals if exist.