BALBOA SUB (serv.man10) - JBL Audio EMC - CB Certificate (repair manual). Page 21

Read JBL BALBOA SUB (serv.man10) EMC - CB Certificate online

 
 
page 17 of 34 
Ref.No.:414744  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to Table 12: 
 
- screws into metal: 5 times 
 
 
- screws into non-metallic material: 10 times 
 
17.2 Correct 
introduction 
into female threads in non-
metallic material 
 P 
17.3 
Cover fixing screws: captive 
 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 P 
17.4 
No loosening of conductive parts carrying a current 
> 0.2 A 
 N 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0.2 A 
 N 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0.2 A with screw terminals not 
consolidated by solder 
 N 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 N 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N 
17.9 
 P 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
18.1 
Picture tube separately approved  ......................... :   
 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used 
with protective screen 
 N 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
Page of 45