Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 33 of 41
5.6 IMMUNITY TO AMBIENT ELECTROMAGNETIC FIELDS (S3)
5.6.1 TEST REQUIREMENT
Test Requirement:
EN 55020
Test Method:
EN 55020
Criterion Required:
A
Wanted Signal:
60dBuV 1KHz FM with 40KHz deviation at 98MHz for FM mode.
1KHz Test sine wave for AUX mode.
Unwanted Signal:
1KHz AM 80% AM at the frequency listed below.
Unwanted signal and immunity limit for FM tuner mode.
Unwanted signal and immunity limit for AUX mode.