ARRAY - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL ARRAY EMC - CB Certificate online

 
 
page 7 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
8.11 
Detaching of wires 
 
No undue reduction of creepage or clearance 
distances if wires become detached 
No risk of any wire becoming 
detached 
N/A 
 
Vibration test carried out  ....................................... : No, no need. See above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 N/A 
8.14 
Adequate fastening of covers (pull test 50 N, for 
10 s) 
 N/A 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1.1 
Touch current measured from terminal devices 
using the network in Annex D  ............................... :
U1 = 0.085V peak  
U2 = 0.025V peak 
 
Discharge not exceeding 45 
µC 
 N/A 
 
Energy of discharge not exceeding 350 mJ 
 
N/A 
 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 N/A 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
 N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe 16 of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
 N/A 
 
If C is not greater than 0.1 
µF no test needed 
 N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N)  ... :  
9.2 
No hazard after removing a cover by hand 
 
N/A 
Page of 47