Read Harman Kardon TU 980 EMC - CB Certificate online
- Page 8 of 38 -
Report
No.
97673
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionising radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13 May
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
No laser radiation.
N/A
Emission limits under fault conditions .................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
No fuse links operate during
normal operating operation.
See appended table
normal operating operation.
See appended table
P
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
°
C
< 0,2 A
N/A
Click on the first or last page to see other TU 980 service manuals if exist.