5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
Signal Generator
Network EMCO 3825/2 90101718
Signal Generator
Anritsu
MG3632A
MT79870
R. C. Oscillator
Kenwood
AG-203A
3090241
DAB Signal Generator
Panasoinc VP7664B 310007A122
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: From December 10, 2007 to December 11, 2007
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner 9.53 60.0 24.7 24.3 50.0 23.6 23.3
FM 20.00 60.0 21.5 21.9 50.0 20.2 20.6
Tuner 5.95 60.0 15.6 15.2 50.0 8.3 10.0
DAB 20.00 60.0 24.2 24.3 50.0 22.7 22.8
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner 9.53 60.0 24.5 24.1 50.0 23.5 22.9
FM 20.00 60.0 18.9 19.4 50.0 17.8 18.3
Tuner 5.95 60.0 28.3 26.5 50.0 19.9 14.9
DAB 20.00 60.0 23.9 24.0 50.0 22.5 22.7
The equipment does comply with the requirements.
For the measurement data, see Annex A (8 Copies).