TU 980 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 16

Read Harman Kardon TU 980 (serv.man3) EMC - CB Certificate online

Reference No. : 54120801A                                                                                                                        Page 15
 
◀  Anam EMC Test Laboratory  ▶
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
1490.624 1  1529.5 46.0  * 
30MHz 
~2.15GHz 
Margin 25.0dB 
 
*: less than 30 ㏈㎶  
 
                                            Limit according to EN55013:2001 
 
8. HARMONICS 
     
8.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 55% 
 
    8.2. Test set-up and procedure 
 
Harmonics of the fundamental current were measured up to 2 ㎑ using a 
 
universal power analyzer. The measurement was carried out under steady   
 
conditions and using averaging. 
 
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2(2000) 
       +A2(2005). 
 
The measurement was performed with the Test software for Windows 
The input signal and load conditions were set as given in clause 4.2.4 of   
IEC 60065. 
 
   8.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Universal power analyzer  Voltech 
PM6000 
100006700178 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
8.4. Test result 
 
The equipment does comply with the requirements. 
For the measurement data, see Annex C (3 Copies). 
 
 
 
 
Page of 88
Display