SUB-TS 8 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon SUB-TS 8 EMC - CB Certificate online

 
 
page 9 of 31 
Ref.No.:413858  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of other parts not subject to the 
limits of 11.2.1 to 11.2.5 
 P 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 Bump 
test 
 
12.1.2 
Vibration test 
No connection or part which 
might impair safety can 
become loose 
12.1.3 Impact 
test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
12.5 
Antenna coaxial sockets providing isolation 
 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.1 
Clearances and creepage distances in accordance 
with 13.2 (fig. 9); minimum distance  ..................... :
Prim.-acc.metal parts: 13mm 
13.1.1 
Reduction applied if the 3 conditions are met  ....... :  
 
Reduction applied for Grade 2 winding wire  ......... :  
13.1.2 
Use of cemented joints .......................................... :  
 
Tests to confirm cemented joints 
 
13.2 
Clearances and creepage distances of parts of 
different polarity connected to the mains, as in 
fig. 9; minimum distance  ....................................... :
3.8mm P 
 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N 
13.3 
Enclosed, enveloped or hermetically sealed parts: 
clearances and creepage distances to Table 4 
 N 
13.4 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 
13.5 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N 
 