Read Harman Kardon SUB-TS 7 EMC - CB Certificate online
page 12 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60738
N
PTC-S devices (15 W) category FV 1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N
14.6
Switches
(See appended table)
14.6.1 Permanently
connected
equipment
provided
with
an all-pole mains switch unless 5.4.2 is met
N
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
Yes
P
Switch readily accessible and not in mains cord
On the rear side. *)
P
Exception
for
automatic
switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
P
Indication by marking meets Cl. 5
POWER
P
Indication
of
the
OFF
position
P
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................ :
fitted, is there a Stand-by mode ............................ :
No Noted
Stand-by mode clearly discernible ........................ :
N
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
N
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
P
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
*) Accepted for this product group.
Click on the first or last page to see other SUB-TS 7 service manuals if exist.