SIGNATURE 2.0 (serv.man11) - Harman Kardon Audio User Guide / Operation Manual. Page 11

Read Harman Kardon SIGNATURE 2.0 (serv.man11) User Guide / Operation Manual online

SIGNATURE
 
B
US 
P
ROTOCOL 
M
ASTER 
D
OCUMENT
Revised 2-24-98
Page 11 of 20
M
AIN 
V
OLUME 
L
EVEL
M
UTE
S
YSTEM 
R
ESET
HEX
COMMAND DESCRIPTION
00
+00  MIN. VOLUME
01
+01
02
+02
03
+03
04
+04
05
+05
06
+06
07
+07
08
+08
09
+09
0A
+10
0B
+11
0C
+12
0D
+13
0E
+14
0F
+15
10
+16
11
+17
12
+18
13
+19
HEX
COMMAND DESCRIPTION
14
+20
15
+21
16
+22
17
+23
18
+24
19
+25
1A
+26
1B
+27
1C
+28
1D
+29
       thru
48
+72
49
+73
4A
+74
4B
+75
4C
+76
4D
+77
4E
+78
4F
+79 MAX.Volume.
. . . . . . . WARNING . . . . . . .
If you are using this feature to
ramp up and down the volume,
you MUST make sure to set
your limits so you do not roll
over to either MAX. or MIN.
volume levels. Speaker damage
will occur if you do roll over to
Max. volume.
Source
Device Type
Target
Device Type
Target
Unit ID
Source
Unit ID
Command
Modifier
Data
Length
Preamble
Byte
Command
Byte
Data
Byte(s)
Checksum
Byte
30h
20h
01h
01h
01h
03h
7Eh
04h
See Below See page 7
Source
Device Type
Target
Device Type
Target
Unit ID
Source
Unit ID
Command
Modifier
Data
Length
Preamble
Byte
Command
Byte
Data
Byte(s)
Checksum
Byte
30h
20h
01h
01h
01h
02h
7Eh
57h
Not used
See page 7
WARNING:  This command resets ALL data to factory defaults.  ALL programming will
be lost.
HEX
COMMAND DESCRIPTION
01
Mute On
02
Mute Off
Source
Device Type
Target
Device Type
Target
Unit ID
Source
Unit ID
Command
Modifier
Data
Length
Preamble
Byte
Command
Byte
Data
Byte(s)
Checksum
Byte
30h
20h
01h
01h
01h
03h
7Eh
05h
See Below See page 7
Page of 19
Display