Technical SpecificaƟons
Description
Specification
Standard and Method of 
Measurement
 
Battery<250 mohm 
Output Voltage 
Typical : 3.7V     Limit : 4.2V 
No Load Condition 
Cut Off Voltage 
Typical : 3.0     Limit : 2.6V 
 
Standard Charging 
Method 
0.5C Constant current charge to 4.2V 
(+/- 0.05V), then constant voltage 
4.2V charge till charge current decline 
to <= 0.05C 
 
Charge current @ onyx 
Studio 
Type:800mA 
 
Charging Time @ onyx 
Studio 
5 hours  
 
Maximum Charge 
Current 
 
 
C
0
.
1
Over charge protection 
voltage 
Min. 4.255V Type:4.28V Max 4.305V 
 
Over charge release 
voltage 
Min. 4.03V Type:4.08V Max:4.13V 
 
Over charge protection 
delay time 
Min: 0.96s Type:1.2s Max:1.4s 
 
Over current detection 
voltage 
Min.0.135V Type:0.16V Max:0.185V 
 
Over current protection 
current 
Min 10.05A Type:12.5A Max:15A 
 
Over discharge 
protection delay time 
Min 115ms Type:144ms Max:173ms 
 
Standard Discharge 
Method 
Discharge current of 0.5C with 3.0V 
cut-off after standard charging. 
 
Cycle Life 
Typical : 80% of initial capacity 
Limit :  75% of initial capacity 
Continuous standard charge and discharge 
for 300 cycles.  The capacity is measured at 
the end of 300 cycles 
Capacity Retention 
Typical : 90% of initial capacity 
Limit :  85% of initial capacity 
Fully charge the battery at 23 +/-5°C, then 
stored it at an ambient temperature for 60 
days.  Measured the capacity after 60 days 
storage with 0.5C discharge at 23 +/-5°C as 
retention capacity.  
Continuous Charge 
Test 
No leakage, no visible evidence of 
electrolyte loss, no explosion and no 
fire. 
The battery discharged at 0.5C 23 +/-5°C, 
then fully charged and held at the specified 
end of charge voltage for total period of 30 
days. 
Over Charging 
Discharging 
No leakage, no visible evidence of 
electrolyte loss, no explosion and no 
fire. 
The battery fully charged at 0.5C 23 +/-5°C, 
discharge the battery at constant 0.5C, until 
battery circuit terminates discharge or at 0V, 
then charge the battery with 0.5C until 
battery circuitry terminates charge or at 
4.2V. Repeat the cycle for 30 times. 
Short Circuit 
No explosion, no fire, maximum 
temperature of battery surface should 
not exceed 150°C 
The battery to be fully charged with 
standard charging condition, and short the 
positive and negative terminal with wire 