Read Harman Kardon ONYX STUDIO 2 (serv.man2) Service Manual online
Technical SpecificaƟons
Description
Specification
Standard and Method of
Measurement
Measurement
Battery<250 mohm
Output Voltage
Typical : 3.7V Limit : 4.2V
No Load Condition
Cut Off Voltage
Typical : 3.0 Limit : 2.6V
Standard Charging
Method
Method
0.5C Constant current charge to 4.2V
(+/- 0.05V), then constant voltage
4.2V charge till charge current decline
to <= 0.05C
(+/- 0.05V), then constant voltage
4.2V charge till charge current decline
to <= 0.05C
Charge current @ onyx
Studio
Studio
Type:800mA
Charging Time @ onyx
Studio
Studio
5 hours
Maximum Charge
Current
Current
C
0
.
1
Over charge protection
voltage
voltage
Min. 4.255V Type:4.28V Max 4.305V
Over charge release
voltage
voltage
Min. 4.03V Type:4.08V Max:4.13V
Over charge protection
delay time
delay time
Min: 0.96s Type:1.2s Max:1.4s
Over current detection
voltage
voltage
Min.0.135V Type:0.16V Max:0.185V
Over current protection
current
current
Min 10.05A Type:12.5A Max:15A
Over discharge
protection delay time
protection delay time
Min 115ms Type:144ms Max:173ms
Standard Discharge
Method
Method
Discharge current of 0.5C with 3.0V
cut-off after standard charging.
cut-off after standard charging.
Cycle Life
Typical : 80% of initial capacity
Limit : 75% of initial capacity
Limit : 75% of initial capacity
Continuous standard charge and discharge
for 300 cycles. The capacity is measured at
the end of 300 cycles
for 300 cycles. The capacity is measured at
the end of 300 cycles
Capacity Retention
Typical : 90% of initial capacity
Limit : 85% of initial capacity
Limit : 85% of initial capacity
Fully charge the battery at 23 +/-5°C, then
stored it at an ambient temperature for 60
days. Measured the capacity after 60 days
storage with 0.5C discharge at 23 +/-5°C as
retention capacity.
stored it at an ambient temperature for 60
days. Measured the capacity after 60 days
storage with 0.5C discharge at 23 +/-5°C as
retention capacity.
Continuous Charge
Test
Test
No leakage, no visible evidence of
electrolyte loss, no explosion and no
fire.
electrolyte loss, no explosion and no
fire.
The battery discharged at 0.5C 23 +/-5°C,
then fully charged and held at the specified
end of charge voltage for total period of 30
days.
then fully charged and held at the specified
end of charge voltage for total period of 30
days.
Over Charging
Discharging
Discharging
No leakage, no visible evidence of
electrolyte loss, no explosion and no
fire.
electrolyte loss, no explosion and no
fire.
The battery fully charged at 0.5C 23 +/-5°C,
discharge the battery at constant 0.5C, until
battery circuit terminates discharge or at 0V,
then charge the battery with 0.5C until
battery circuitry terminates charge or at
4.2V. Repeat the cycle for 30 times.
discharge the battery at constant 0.5C, until
battery circuit terminates discharge or at 0V,
then charge the battery with 0.5C until
battery circuitry terminates charge or at
4.2V. Repeat the cycle for 30 times.
Short Circuit
No explosion, no fire, maximum
temperature of battery surface should
not exceed 150°C
temperature of battery surface should
not exceed 150°C
The battery to be fully charged with
standard charging condition, and short the
positive and negative terminal with wire
standard charging condition, and short the
positive and negative terminal with wire
Click on the first or last page to see other ONYX STUDIO 2 (serv.man2) service manuals if exist.