Read Harman Kardon HS 2X0 (serv.man4) EMC - CB Certificate online
Test report no. SH09100839-001
Page 12 of 106
TRF55013a/effective date: September 15
th
, 2009
Emission Test
3. Disturbance voltage at the mains terminals
Test result:
PASS
3.1 Limits of disturbance voltage at the mains terminals
Frequency range
(MHz)
Limits dB(
μv)
Quasi-peak Average
0.15 ~ 0.5
66 ~ 56 *
59 ~ 46 *
0.5 ~ 5
56
46
5 ~ 30
60
50
Note: 1. * means the limit decreasing linearly with the logarithm of the frequency.
2. If the limits for the average detector are met when using the quasi-peak
detector, then the limits for the measurements with the average detector
are considered to e met.
are considered to e met.
3.2 Test setup