HS 1000 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon HS 1000 (serv.man2) EMC - CB Certificate online

 
                                                                   Page 5 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation 
N/A 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
No ionizing radiation 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... : Class 1 
Pass 
 
Emission limits under fault conditions .................... : Laser Optical Pickup: Class 1  
Pass 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table) 
Pass 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
Pass 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
Pass 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
Pass 
7.1.4 
Temperature rise of windings 
(see appended table) 
Pass 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such supporting parts 
N/A 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB, windings 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools are required 
Pass 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
Pass 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
Tools are required 
Pass 
8.5 
Class I equipment 
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
Page of 68
Display

Click on the first or last page to see other HS 1000 (serv.man2) service manuals if exist.