Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
J.2
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification
:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
distribution system where the neutral is not
provided.
N/A