HKTS 7 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 27

Read Harman Kardon HKTS 7 (serv.man2) EMC - CB Certificate online

 
 
page 23 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : 220-240 
 
 
Ambient temperature (
°C) ..................................... : 22 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 22 
 
 
Ambient temperature t2 (ºC)  ................................. : 22 
 
No
Component 
No. 
Fault  Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
1 Max. 
non-
clipping 
output 
power  
(pink noise) 
-- 254.4  4h 
Mains 
fuse 
0.55 
Pn= 104W, In= 0.55A. 
Transf. prim. winding dT = 78K 
Transf. sec. windings dT = 68-
72K 
Enclosure (metal) = 44K 
Heat sink (exterior) = 48K 
No remarks. 
2 Q105  sc  254.4  --  Mains 
fuse 
>2.6A 
Q107 and Q108 broke, mains 
fuse opened immediately. 
No remarks. 
3 Q107  sc  254.4  --  Mains 
fuse 
>2.6A 
Q107 and Q108 broke, mains 
fuse opened immediately. 
No remarks. 
4 C133  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse opened immediately. 
No remarks. 
5 D115 
(  -  ) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse opened immediately. 
No remarks. 
6 D110 
(  -  ) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse opened immediately. 
No remarks. 