HKTS 210SUB - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 31

Read Harman Kardon HKTS 210SUB EMC - CB Certificate online

Page 31 of 56 
 
Report No.1018947 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
13 
TABLES: clearances and creepage distances 
Rated supply voltage: 
220-240V 
Pollution degree: 
Material Group: 
IIIb 
2 N force on internal parts applied: 
30 N force on outside of conductive enclosure applied: 
N/A 
Location 
Operating Voltage 
Clearance (mm) 
Creepage (mm) 
 
V rms 
V peak 
Min 
Actual 
Min 
Actual 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
Primary (ac) to Earth (B) 
Primary (+dc) to Earth max (B) 
Primary (-dc) to Earth max (B) 
Across mains fuse F1 (B) 
240 
339 
2.0 
1.25 
2.4 
1.25 
Across primary directly connected to the 
mains (B) 
240 339  2.0  5.0 2.4 5.0 
Hazardous live secondary to Earth (B) 
Optocoupler input to output (R) 
44*/240 83*/339 
0.8 
5.3  0.8*/2.2
5.3 
Primary to Secondary in CT1 (R) 
124*/240 223*/339 
4.0 
5.5 
3.0*/4.8
5.5 
Primary to Secondary in T1 (R) 
130*/240
358* 
4.0 
5.0 
3.2*/4.8
5.0 
Primary to Secondary in T2 (R) 
178*/240 295*/339 
4.0 
7.6 
3.8*/4.8
7.6 
Primary to Secondary in DT1 (R) 
134*/240 257*/339 
4.0 
7.0 
3.2*/4.8
7.0 
Primary to accessible conductive parts (R) 
240 339*/339  4.0 
6.1 
4.8 
6.1 
Primary to Secondary PWB (R) 
44*/240 
83*/339 
4.0 
5.4 
2.4*/4.8
5.4 
Hazardous live secondary to non-
hazardous live secondary (R) 
- -  - - - - 
Hazardous live secondary to unearthed 
conductive enclosure (R) 
- -  - - - - 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance . 
"Min" = minimum required.
 
"Actual = Actual dimensions measured.     
The actual value measured*/ required value 
Page of 56