Read Harman Kardon HKTS 11 (serv.man14) EMC - CB Certificate online
Page 8 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ....:
N/A
Emission limits under fault conditions ....................:
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
o
C
Mains fuse holder
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
PCB
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
Tools are required.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
Not used.
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
Transformer
P