Read Harman Kardon HKTS 11 (serv.man12) EMC - CB Certificate online
File No.
F24258-02-00HM
, page 1 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
EMC -- T E S T R E P O R T
Test Report No. :
F24258-02-00HM
11. October 2004
______________________________________________________________________________________________
Date of issue
Type / Model
: Harman Kardon SUB-TS 11
Model Description
: Powered Subwoofer
Applicant : Harman Consumer Group
Address
: 250 Crossways Park Drive, Woodbury
New York 11797-2015, USA
Manufacturer : Dongguan Meiloon Acoustic Equipments Co. Ltd.
Address
: Feng Huang Gang Ind. Estate, Tangxia
Dongguan, Guang Dong Province, China
Test Result
according to the
standards listed in clause 1 test
standards:
standards:
POSITIVE
The test report merely corresponds to the test sample.
It is not permitted to copy extracts of these test results without the written permission of the test laboratory.
It is not permitted to copy extracts of these test results without the written permission of the test laboratory.
File No.
F24258-02-00HM
, page 2 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
Contents
1
T E S T S T A N D A R D S
3
2
S U M M A R Y
4
3
E Q U I P M E N T U N D E R T E S T
5
3.1
P
HOTO DOCUMENTATION OF THE
E
U
T 5
3.2
P
OWER SUPPLY SYSTEM UTILISED
6
3.3
S
HORT DESCRIPTION OF THE
E
QUIPMENT UNDER
T
EST
(E
U
T) 6
3.4
P
ERFORMANCE LEVEL
7
4
T E S T E N V I R O N M E N T
8
4.1
A
DDRESS OF THE TEST LABORATORY
8
4.2
E
NVIRONMENTAL CONDITIONS
8
4.3
S
TATEMENT OF THE MEASUREMENT UNCERTAINTY
8
5
T E S T C O N D I T I O N S A N D R E S U L T S
9
5.1
C
ONDUCTED DISTURBANCE
9
5.2
D
ISTURBANCE POWER
12
5.3
H
ARMONIC CURRENT
15
5.4
V
OLTAGE FLUCTUATIONS AND FLICKER
17
5.5
I
MMUNITY REQUIREMENTS
-
S2 19
5.6
I
MMUNITY REQUIREMENTS
-
S3 20
5.7
E
LECTROSTATIC DISCHARGE
21
5.8
R
ADIATED
,
RADIO
-
FREQUENCY
,
ELECTROMAGNETIC FIELD
23
5.9
E
LECTRICAL FAST TRANSIENTS
/
B
URST
24
6
U S E D T E S T E Q U I P M E N T A N D A C C E S S O R I E S
2 6
A T T A C H M E N T
A 1 – A 1 0
File No.
F24258-02-00HM
, page 3 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
1 T E S T S T A N D A R D S
The tests were performed according to following standards:
EN 55013
: 2001
EN 55020
: 2002
EN 61000-4-1
: 2000
EN 61000-4-2
: 1995 +A1: 1998 + A2: 2001
EN 61000-4-3
: 1996 +A1: 1998 + A2: 2001
EN 61000-4-4
: 1995 +A1: 2001 + A2: 2001
EN 61000-4-5
: 1995 +A1: 2001
EN 61000-4-6
: 1996 +A1: 2001
EN 61000-4-7
: 2000
EN 61000-4-8
: 1993 +A1: 2001
EN 61000-4-9
: 1993 +A1: 2001
EN 61000-4-10
: 1993 +A1: 2001
EN 61000-4-11
: 1994 +A1: 2001
EN 61000-4-12
: 1995 +A1: 2001
EN 61000-3-2
: 2000
EN 61000-3-3
: 1995 +A1: 2001
EN 61000-3-11
: 2000