HK 3390 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 51

Read Harman Kardon HK 3390 EMC - CB Certificate online

IEC 60065   7ed. (2001) 
 
- Page 1 of 3 - 
 
 
www.nemko.com
 
Report No.  98502 
 
 
 
ATTACHMENT: Tables to EN/IEC 60065 7
th
 edition
 
 
 
 
9.1.1.1 
Touch current expressed as voltages U1 and U2 in Annex D 
Location 
Measured U1V 
(peak) 
Measured U1
V (DC) 
Measured U2 
V (peak) 
Limits :  
U1 Max 35V (peak) 
U1 Max  1.1V (DC) 
U2 Max 0.35V (peak)
Pole 1 - Antenna terminal 
Pole 2 - Antenna terminal 


0,03Vpeak 
0,01Vpeak 
Pass 
Pass 
Pole 1 - other part or contact 
Pole 2 - other part or contact 


0,03Vpeak 
0,01Vpeak 
Pass 
Pass 
 
 
 
 
 
Comments: 
Vin = 253Vac, 60Hz 
Only U2 have been recorded due to the use of a linear transformer in power supply. 
 