Read Harman Kardon HK 3390 EMC - CB Certificate online
IEC 60065 7ed. (2001)
- Page 1 of 3 -
www.nemko.com
Report No. 98502
ATTACHMENT: Tables to EN/IEC 60065 7
th
edition
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location
Measured U1V
(peak)
(peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 - Antenna terminal
Pole 2 - Antenna terminal
Pole 2 - Antenna terminal
-
-
-
-
-
-
0,03Vpeak
0,01Vpeak
0,01Vpeak
Pass
Pass
Pass
Pole 1 - other part or contact
Pole 2 - other part or contact
Pole 2 - other part or contact
-
-
-
-
-
-
0,03Vpeak
0,01Vpeak
0,01Vpeak
Pass
Pass
Pass
Comments:
Vin = 253Vac, 60Hz
Only U2 have been recorded due to the use of a linear transformer in power supply.