Reference No. : 54120801G                                                                                                                        Page 7
 
◀  Anam EMC Test Laboratory  ▶
 
 
5.4. Test instrument 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Shielded room 
Measurement 
                      Receiver 
R & S 
ESCI 
100348 
R & S 
ESH3-Z5 
844249/020 
Artificial mains 
                      Network  EMCO 3825/2 90101718 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
 
* R & S: Rohde & Schwarz 
 
5.5. Test protocol 
 
 
Date: January 16, 2008 
 
Grounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A. 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
Tuner 
5.596 56.0 17.6 17.7 46.0 12.7 12.8 
 
 
 
 
 
 
 
 
 
 
Ungrounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
Tuner 
5.596 56.0 27.2 26.0 46.0 23.8 21.0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CD 5.596 56.0 25.9 24.0 46.0 23.0 15.5 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex A (6 Copies). 
 
 
 
 